Product standard to demonstrate the compliance of wireless communication devices, with the basic restrictions and exposure limit values related to human exposure to electromagnetic fields in the frequency range from 300 MHz to 6 GHz: devices used next to the ear; German version EN 50360:2017 + A1:2023
Abstract
This draft standard contains the German version of the draft Amendment 1 to European Standard EN 50360:2017 and intends to add new SAR measurement technique that have been adopted with EN IEC 62209-3:2019. The standard contains requirements related to human exposure to electromagnetic fields from wireless communication devices in the frequency range 300 MHz to 6 GHz. This product standard applies to wireless communication devices e.g. mobile phones and headsets that are used in close proximity to the human ear. The objective of this standard is the demonstration of compliance of the equipment covered by this standard with the basic restrictions (Specific Absorption Rate (SAR)) which are specified for the for safety of the general public in radio-frequency electromagnetic fields and exposure limits which are specified for the for safety of workers.
Begin
2020-09-30
Planned document number
DIN EN 50360
Project number
02229766
Responsible national committee
DKE/K 764 - Sicherheit in elektromagnetischen Feldern
draft standard
Product standard to demonstrate the compliance of wireless communication devices, with the basic restrictions and exposure limit values related to human exposure to electromagnetic fields in the frequency range from 300 MHz to 6 GHz: devices used next to the ear; German and English version EN 50360:2017/prA1:2020
2021-03
Order from DIN Media