• Hydrogen Technologies Standards form the basic framework for market ramp-up

    More information
  • Climate change Standards and specifications support climate targets

    More information
  • Smart Farming Standards and specifications are drivers for the digitalization of agriculture

    More information
Technical Specification

DIN CLC/TS 50131-2-11 ; VDE V 0830-2-2-11:2017-12
Alarm systems - Intrusion and hold-up systems - Part 2-11: Intrusion detectors - ALDDR; German version CLC/TS 50131-2-11:2017

Title (German)

Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil 2-11: Einbruchmelder - ALDDR; Deutsche Fassung CLC/TS 50131-2-11:2017

Procedure

VN

Overview

This Technical Specification covers active laser detectors responsive to diffuse reflection (to be designated ALDDR) that are installed in buildings and used as part of intruder alarm systems. It provides for four security levels and four environmental classes. The purpose of an ALDDR is to detect an intruder within a predetermined area and to provide the necessary range of signals and messages for use by the rest of the intruder detection system. The responsible committee is DKE/UK 713.1 "Gefahrenmelde- und Überwachungsanlagen" ("Alarm and surveillance systems") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.

Document: references other documents

Responsible national committee

DKE/UK 713.1 - Gefahrenmelde- und Überwachungsanlagen  

Edition 2017-12
Original language German
Price from 95.25 €
Table of contents

Contact

Nematullah Popalzai

Merianstr. 28
63069 Offenbach am Main

Tel.: +49 69 6308-576

Send message to contact