DIN EN 16573
Ventilation for Buildings - Performance testing of components for residential buildings - Multifunctional balanced ventilation units for single family dwellings, including heat pumps; German version EN 16573:2017
Lüftung von Gebäuden - Leistungsprüfung von Bauteilen für Wohnbauten - Multifunktionale Zu-/Abluft-Lüftungseinheiten für Einzelwohnungen, einschließlich Wärmepumpen; Deutsche Fassung EN 16573:2017
Overview
Ventilation units that have different functions are increasingly used to ventilate homes. These multifunctional ventilation units that are intended for use in a single dwelling and initially intended to provide balanced ventilation may also be used for heating and/or cooling and/or hot water generation. The standard DIN EN 16573 specifies the laboratory test methods and test requirements for aerodynamic, energy rating and acoustic performance, of multifunctional balanced units intended for use in a single dwelling. In the case of units consisting of several parts, this standard applies only to those designed and supplied as a complete package with the mount instructions. It covers units that contain at least, within one or more casing: - supply and exhaust air fans; - air filters - common control system; and one or more of the additional components: - air to water heat pump; - air to air heat pump; - air-to-air heat exchanger. Units including only an air to air heat exchanger and/or an exhaust air to supply air heat pump are covered by EN 13141-7. The standard does not cover the thermal aspects of humidity transfer in the air-to-air heat exchanger. This standard does not deal with non-ducted units on supply and extract air side. This standard does not deal with collective units (centralized or semi-centralized systems). These multifunctional balanced units can be connected to ground heat exchanger for air preheating, solar collector or other heating systems. This standard does not cover the testing with these additional components. This standard does not cover units including combustion engine driven compression heat pumps and sorption heat pump. This document has been prepared by WG 16 "Joint Working Group between CEN/TC 156 and CEN/TC 113 - Multifunctional balanced ventilation units for single family dwellings, including heat pumps" within Technical Committee CEN/TC 156 "Ventilation for buildings" (secretariat: BSI, United Kingdom) of the European Committee for Standardization (CEN). Working Committee NA 041-02-51 AA "Lüftung von Wohnungen" ("Residential ventilation") at DIN Standards Committee Heating and Ventilation Technology and their Safety (NHRS) was involved in the preparation.
Document: references other documents
Responsible national committee
NA 041-02-51 AA - Residential ventilation (Mirror committee CEN/TC 156/WG 2 and CEN/TC 156/WG 16)