DIN EN 50288-11-2
; VDE 0819-11-2:2016-04
Multi-element metallic cables used in analogue and digital communication and control - Part 11-2: Sectional specification for un-screened cables, characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications; German version EN 50288-11-2:2015
Mehradrige metallische Daten- und Kontrollkabel für analoge und digitale Kommunikation - Teil 11-2: Rahmenspezifikation für ungeschirmte Kabel von 1 MHz bis 500 MHz für Geräteanschlusskabel, Schaltkabel und Anwendungen für Rechenzentren; Deutsche Fassung EN 50288-11-2:2015
Overview
This sectional specification covers screened cables, characterised from 1 MHz to 500 MHz, to be used as work area cables to connect a telecommunications outlet to the terminal equipment and for patch cord cables to establish connections on a patch panel as defined in EN 50173. Work area and data centres cables may also be used as patch cord cables in any distributor of a generic building wiring system to interconnect with equipment or to cross-connect between cabling systems. This sectional specification contains the electrical, mechanical, transmission and environmental performance characteristics and requirement of the cables when tested in accordance with the referenced test methods. This sectional specification should be read in conjunction with EN 50288-1, which contains the essential provisions for its application. The cables covered in this sectional specification are intended to operate with voltages and currents normally encountered in communication systems. These cables are not intended to be used in conjunction with low impedance sources, for example, the electric power supplies of public utility mains. For the application of this document, the terms according to EN 50288-1 and the term cable screening apply. A cable is considered to be screened if the cable core is provided with a continuous conductive layer which is part of the screening and grounding system. Informative Annex A provides recommended maximum voltage, current, current density, and conductor temperature values for cables used in POE applications. Informative Annex B contains the form for design specification of screened cables for horizontal and building backbone cables from 1 MHz to 500 MHz for use in industrial or rough environmental conditions. The responsible committee is DKE/UK 412.1 "Symmetrische Kabel und Leitungen, Drähte" ("Symmetric cables and conductors, wires") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.