• Hydrogen Technologies Standards form the basic framework for market ramp-up

    More information
  • Climate change Standards and specifications support climate targets

    More information
  • Smart Farming Standards and specifications are drivers for the digitalization of agriculture

    More information
Standards [CURRENT]

DIN EN 50299-2
Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 2: Dry-type cable terminations; German version EN 50299-2:2014

Title (German)

Ölgefüllte Kabelanschlusseinheiten mit Kompaktkabelanschlüssen für Transformatoren und Drosselspulen mit einer höchsten Spannung für Betriebsmittel Um von 72,5 kV bis 550 kV - Teil 2: Kompaktkabelanschlüsse; Deutsche Fassung EN 50299-2:2014

Overview

EN 50299-2 covers the oil-immersed single-phase connection assemblies of cables for transformers and reactors designed in accordance with EN 60076 (all parts). This standard applies to oil-filled cable connection boxes of transformers with highest voltage for equipment from Um = 72,5 kV to Um = 550 kV, including the conductor current terminal with removable link between the transformer and the dry-type cable termination. It complements and amends, if necessary, the relevant standards and applies to dry-type cable terminations for power cables with extruded insulation which may be used with similar interfaces for the cable entrance in switchgear applications according to EN 62271-209. The purpose of EN 50299-2 is to establish for the cable connection assemblies: electrical and mechanical requirements including interchangeability, limits of supply, tests to be carried out. If no separate cable connection box is used and dry-type cable terminations are directly installed into the transformer tank the requirements of this standard should be followed. EN 50299-2 partially supersedes EN 50299:2002, together with EN 50299-1:2014. The new standard EN 50299-2 is issued which describes requirements for dry-type cable terminations only. Dimensions mentioned in 50922-1 are valid for fluid-filled cable terminations. Dry-type cable terminations may also fit to these requirements. The responsible committee is Subcommittee DKE/UK 321.2 "Transformatoren, Leistungen und Abmessungen" ("Transformers, performances and dimensions") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.

Document: references other documents

Responsible national committee

DKE/UK 321.2 - Transformatoren, Leistungen und Abmessungen  

Edition 2015-08
Original language German
Price from 99.10 €
Table of contents