DIN EN 50134-3
; VDE 0830-4-3:2012-11
Alarm systems - Social alarm systems - Part 3: Local unit and controller; German version EN 50134-3:2012
Alarmanlagen - Personen-Hilferufanlagen - Teil 3: Örtliche Zentrale und Übertragungsgerät; Deutsche Fassung EN 50134-3:2012
Overview
This standard specifies the minimum requirements for the local unit and controller to ensure this system part provides the functionality and reliability required by a social alarm system. This standard applies to local units and controllers that receive an alarm triggering signal from manually or automatically activated trigger devices and convert this into an alarm signal for transmission to the alarm receiving centre or an alarm recipient. The local unit and controller may be either separate units or integrated into one unit. The responsible committee is UK 713.1 "Gefahrenmelde- und Überwachungsanlagen" ("Alarm and surveillance systems") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.