DIN CLC/TS 50537-1
; VDE V 0115-537-1:2011-04
Railway applications - Mounted parts of the traction transformer and cooling system - Part 1: HV bushing for traction transformers; German version CLC/TS 50537-1:2010
Bahnanwendungen - Anbauteile des Haupttransformators und Kühlsystems - Teil 1: Hochspannungsdurchführung für Haupttransformatoren; Deutsche Fassung CLC/TS 50537-1:2010
Procedure
VN
Overview
This Technical Specification is applicable to high voltage (HV) bushings, intended for use in traction transformers of rail vehicles, cooled by insulating liquid with rated voltages up to 25 kV (single phase) and rated currents up to 630 A at frequencies from 16,7 Hz to 60 Hz. HV bushings within the framework of this Technical Specification are bushings for separable connectors that connect the power supply coming from a contact wire or from a contact rail to the primary winding of the traction transformer. The Technical Specification only deals with HV bushings that are mounted to the transformer. CLC/TS 50537-1 gives consideration to both technical and normative requirements of the railway environment and restricts the variety provided by industry standards, such as EN 50180 and EN 60137. It specifies requirements and tests enabling the interchangeability, especially regarding electrical and mechanical interfaces. Furthermore, operating conditions are described. The cable plug as the counterpart of the HV bushing's plug-in end is not covered by this Technical Specification. The responsible Committee is Subcommittee UK 351.1 "Fahrzeuge" ("Rolling stock") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.