NA 062

DIN Standards Committee Materials Testing

Project

Determination of flash point - Pensky-Martens closed cup method

Abstract

ISO 2719:2016 describes three procedures, A, B and C, using the Pensky-Martens closed cup tester, for determining the flash point of combustible liquids, liquids with suspended solids, liquids that tend to form a surface film under the test conditions, biodiesel and other liquids in the temperature range of 40 °C to 370 °C. CAUTION - For certain mixtures no flash point, as defined, is observed; instead a significant enlargement of the test flame (not halo effect) and a change in colour of the test flame from blue to yellowish-orange can occur. Continued heating can result in significant burning of vapours outside the test cup, and can be a potential fire hazard. NOTE 1 Although, technically, kerosene with a flash point above 40 °C can be tested using this International Standard, it is standard practice to test kerosene according to ISO 13736.[5] Similarly, lubricating oils are normally tested according to ISO 2592[2]. Procedure A is applicable to distillate fuels (diesel, biodiesel blends, heating oil and turbine fuels), new and in-use lubricating oils, paints and varnishes, and other homogeneous liquids not included in the scope of Procedures B or C. Procedure B is applicable to residual fuel oils, cutback residua, used lubricating oils, mixtures of liquids with solids, liquids that tend to form a surface film under test conditions or are of such kinematic viscosity that they are not uniformly heated under the stirring and heating conditions of Procedure A. Procedure C is applicable to fatty acid methyl esters (FAME) as specified in specifications such as EN 14214[11] or ASTM D6751[13]. ISO 2719:2016 is not applicable to water-borne paints and varnishes. NOTE 2 Water-borne paints and varnishes can be tested using ISO 3679[3]. Liquids containing traces of highly volatile materials can be tested using ISO 1523[1] or ISO 3679.

Begin

2024-04-17

WI

00019666

Planned document number

prEN ISO 2719 rev

Responsible national committee

NA 062-06-42 AA - Testing of liquid fuels and fuel oils  

Responsible european committee

CEN/TC 19 - Gaseous and liquid fuels, lubricants and related products of petroleum, synthetic and biological origin  

previous edition(s)

Determination of flash point - Pensky-Martens closed cup method - Amendment 1: Thermometers correction (ISO 2719:2016/Amd 1:2021)
2021-03

Order from DIN Media

Determination of flash point - Pensky-Martens closed cup method (ISO 2719:2016)
2016-07

Order from DIN Media