NA 041

DIN Standards Committee Heating and Ventilation Technology and their Safety

Project

Water supply - Indirectly heated unvented (closed) storage water heaters - Part 1: General specifications and common test methods

Abstract

This document specifies the general specifications, constructional requirements and common test methods for indirectly heated, unvented (closed) storage water heaters of up to 2 000 l volume suitable for connection to a water supply at a pressure between 0,05 MPa and 1,0 MPa (0,5 bar and 10 bar), and fitted with control and safety devices designed to prevent the temperature of the stored drinking water from reaching 95 °C. Whilst storage water heaters intended primarily for direct heating are not covered by this document, it does allow the provision of electric heating elements for auxiliary use. Additional requirements for storage water heaters using vitreous enamel for corrosion protection are specified in EN 12897-2.

Begin

2024-05-22

WI

00164771

Planned document number

prEN 12897-1

Responsible national committee

NA 041-01-45 AA - Water heaters (Mirror committee CEN/TC 164/WG 10)  

Responsible european committee

CEN/TC 164/WG 10 - Hot water and cold water storage within dwellings  

previous edition(s)

Water supply - Specification for indirectly heated unvented (closed) storage water heaters
2020-02

Order from DIN Media

Contact

Saleh Darwiche

Am DIN-Platz, Burggrafenstr. 6
10787 Berlin

Tel.: +49 30 2601-2629
Fax: +49 30 2601-42629

Send message to contact