NA 119

DIN Standards Committee Water Practice

Project

Piping systems for rehabilitation of underground drainage, sewerage and water supply networks - Part 2: Thermoset composite materials

Abstract

This document specifies requirements and test methods for pipes and fittings which are part of piping systems for the rehabilitation of underground non-pressure and pressure drainage and sewerage networks, and of water supply networks which transport water intended for human consumption, including raw water intake pipelines. It is applicable to the renovation technique family: - lining with cured-in-place pipes (CIPP). It applies to the use of thermoset composite materials with various thermosetting resin systems, in combination with compatible fibrous carrier materials, reinforcement, and other process-related plastics components (see 5.1). It is applicable to pipes and fittings, as manufactured, as well as to the installed system, with service temperatures up to 50 °C for drainage and sewerage networks and up to 25°C for water supply networks. For pressurised networks, this document applies to independent (fully structural, class A) and interactive (semi structural, class B) pressure pipe liners, as defined in ISO 11295, which do not rely on adhesion to the existing pipeline. It does not include requirements or test methods for resistance to abrasion, cyclic loading or impact, which are outside the scope of this document.

Begin

2024-03-22

WI

00155A1P

Planned document number

prEN ISO 11300-2

Responsible national committee

NA 119-05-37 AA - Renovation, repair and replacement of drains and sewers (CEN/TC 165/WG 13, CEN/TC 155/WG 17 and ISO/TC 138/SC 8 with WG 1, WG 2 and WG 7)  

Responsible european committee

CEN/TC 155/WG 17 - Rehabilitation of pipeline systems  

previous edition(s)

Plastics piping systems for renovation of underground water supply networks - Part 4: Lining with cured-in-place pipes (ISO 11298-4:2021)
2021-04

Order from DIN Media

Plastics piping systems for renovation of underground water supply networks - Part 1: General (ISO 11298-1:2018)
2018-04

Order from DIN Media

Plastics piping systems for renovation of underground drainage and sewerage networks under pressure - Part 4: Lining with cured-in-place pipes (ISO 11297-4:2018)
2018-02

Order from DIN Media

Plastics piping systems for renovation of underground drainage and sewerage networks under pressure - Part 1: General (ISO 11297-1:2018)
2018-04

Order from DIN Media

Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - Part 4: Lining with cured-in-place pipes - Amendment 1: Updated definitions, marking requirements and procedure for alternative expression of flexural test results (ISO 11296-4:2018/Amd 1:2021)
2021-05

Order from DIN Media

Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - Part 4: Lining with cured-in-place pipes (ISO 11296-4:2018)
2018-02

Order from DIN Media

Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - Part 1: General (ISO 11296-1:2018)
2018-03

Order from DIN Media

Contact

Natja Böttcher

Am DIN-Platz, Burggrafenstr. 6
10787 Berlin

Tel.: +49 30 2601-2139
Fax: +49 30 2601-42139

Send message to contact