NA 152

DIN Standards Committee Technical Fundamentals

Project

PN 250 and PN 400 valves with shut-off test connection for pressure gauges

Abstract

This document is applicable to valves for pressure gauges for use in pressure measuring setups for liquids, gases and vapours, with shut-off test connection, for a maximum allowable pressure of 250 bar (brass) and 400 bar (steel and stainless steel) and a maximum allowable temperature of 120 °C.

Two design types are specified:

  • Form A: with adjusting nut;
  • Form B: with nipple connection and shaft for measuring instruments supports according to DIN 16281.

This document does not cover sealing washers; for these, DIN EN 837-1 applies. DIN 16270 applies to valves PN 250 and PN 400 without shut-off connection. Für Absperrventile PN 250 und PN 400 mit nicht getrennt absperrbarem Prüfanschluss ist DIN 16271 applies to valves PN 250 and PN 400 with test connections without shut-off function.

Begin

2024-09-04

Planned document number

DIN 16272

Project number

15202928

Responsible national committee

NA 152-04-01 AA - Mechanical gauges for pressure and temperatur  

previous edition(s)

PN 250 and PN 400 valves with shut-off test connection for pressure gauges
2004-07

Order from DIN Media

Contact

Tobias Hübner

Am DIN-Platz, Burggrafenstr. 6
10787 Berlin

Tel.: +49 30 2601-2988
Fax: +49 30 2601-42988

Send message to contact