DIN Standards Committee Health Technologies
Sterilizers for medical purposes - Low temperature steam and formaldehyde sterilizers - Requirements and testing; German version FprEN 14180:2024
Abstract
1.1 This document specifies requirements and tests for LTSF sterilizers, which use a mixture of low temperature steam and formaldehyde as sterilizing agent, and which are working below ambient pressure only.
These sterilizers are primarily used for the sterilization of heat labile medical devices in health care facilities.
1.2 This document specifies minimum requirements:
- for the performance and design of sterilizers intended to deliver an LTSF-process capable of sterilizing medical devices;
- for the equipment and controls of these sterilizers needed for operation, control and monitoring of the sterilization processes, and which can be used for validation of the sterilization process.
1.3 This document specifies further test equipment and test procedures used to verify conformance of the equipment design and performance specified by this document.
1.4 This document does not specify requirements and tests for decontamination systems for use in rooms, enclosures, or environmental spaces.
Begin
2022-03-01
WI
00102168
Planned document number
DIN EN 14180
Project number
06302141
Responsible national committee
NA 176-03-04 AA - Low temperature sterilizers
Responsible european committee
CEN/TC 102/WG 6 - Low temperature sterilizers
draft standard
Sterilizers for medical purposes - Low temperature steam and formaldehyde sterilizers - Requirements and testing; German and English version prEN 14180:2023
2023-04
Order from DIN Media