NA 005

DIN Standards Committee Building and Civil Engineering

Project

Windows, doors, shutters and curtain walling - Explosion resistance - Requirements and classification - Part 2: Arena test

Abstract

This document specifies the criteria, which windows, doors, shutters as well as curtain walling elements need to satisfy to achieve a classification when submitted to the test method described in prEN 13124-2:2023. This document concerns a method of test against blast waves produced by high explosives in an arena test. This document considers free-field high explosive events equivalent to: - 3 kg to 20 kg (TNT equivalent) at distances from 3 m to 9 m, described by the fixed classification levels PXR 1 to PXR 7; - 100 kg to 500 kg (TNT equivalent) at distances from about 15 m to 30 m, described by the fixed classification levels VXR 1 to VXR 7. It produces a classification according to prEN 13124 2:2023. Indicative charge sizes and stand-off distances producing these loading levels are shown in Annex B. Blast loadings characterised by user specified blast parameters for other high explosive scenarios can also be specified. Blast loads which cannot be produced in an arena test might be produced by a shock tube test following prEN 13123-1:2022 and prEN 13124-1:2022. This document is applicable to blast waves generated by explosives in an arena test facility to produce high explosive blast loads on windows, doors and shutters as well as curtain walling systems, complete with their frames, infills and fixings, for use in both internal and external locations in buildings. It gives no information on the explosion resistance capacity of the wall or other surrounding structure.

Begin

2022-09-01

WI

00033593

Planned document number

prEN 13123-2

Responsible national committee

NA 005-09-01 AA - Doors, windows, shutters, building hardware and curtain walling (national mirror committee for CEN/TC 33 and ISO/TC 162)  

Responsible european committee

CEN/TC 33 - Doors, windows, shutters, building hardware and curtain walling  

draft standard

Windows, doors, shutters and curtain walling - Explosion resistance - Requirements and classification - Part 2: Arena test
2023-08
Order from DIN Media

previous edition(s)

Windows, doors and shutters - Explosion resistance - Requirements and classification - Part 2: Range test
2004-02

Order from DIN Media

Contact

Dr.-Ing.

Tristan Herbst

Am DIN-Platz, Burggrafenstr. 6
10787 Berlin

Tel.: +49 30 2601-2514
Fax: +49 30 2601-42514

Send message to contact