DIN Standards Committee Valves
DIN 11853-2
Stainless steel fittings for the food and chemical industry - Part 2: Hygienic flanged pipe connection, short type
Armaturen aus nichtrostendem Stahl für Lebensmittel und Chemie - Teil 2: Hygiene-Flanschverbindung, kurze Ausführung
Overview
This standard applies for dimensions, design and materials of hygienic screwed pipe connections with o-ring, short type for butt welding to pipes with dimensions according to DIN 11866 and DIN 11850, series 2. The hygienic screwed pipe connections are designed for the following permissible pressures: - tube outside diameter from 12,7 mm to 41,0 mm: 2,5 MPa (25 bar); - tube outside diameter from 42,4 to 104,0 mm: 1,6 MPa (16 bar); - tube outside diameter from 114,3 mm to 154,0 mm: 1,0 MPa (10 bar). These pressures in MPa (bar) can be applied when suitable sealing materials from -10 °C to +140 °C are used. This document has been prepared by Working Committee NA 003-01-14 AA "Armaturen für die Lebensmittelindustrie" ("Valves for the food industry") based on recommendations of the EHEDG (European Hygienic Equipment Design Group) Subgroup pipe-couplings.
Document: references other documents
Document: referenced in other documents
Responsible national committee
NA 003-01-14 AA - Tubes and components for food, chemical and pharmaceutical industries