VDI/DIN-Commission on Air Pollution Prevention (KRdL) - Standards Committee
DIN EN 12619
Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method; German version EN 12619:2013
Emissionen aus stationären Quellen - Bestimmung der Massenkonzentration des gesamten gasförmigen organisch gebundenen Kohlenstoffs - Kontinuierliches Verfahren mit dem Flammenionisationsdetektor; Deutsche Fassung EN 12619:2013
Overview
This European Standard specifies a flame ionisation detector (FID) method. It is intended for use as a standard reference method for the measurement of the mass concentration of gaseous and vaporous organic substances (expressed as TVOC (total volatile organic carbon (TVOC))) in stationary source emissions (for example, emissions from waste incinerators and solvent using processes, emission measurements according to 2010/75/EU) in the concentration range up to 1 000 mg/m3. This European Standard specifies the requirements for an instrument using flame ionisation detection, together with procedures for its operation. The results obtained using this standard are expressed in milligrams per cubic metre (mg/m3) as total carbon (TVOC). This European Standard is not applicable for permanently installed automated measuring systems (AMS). This standard is relevant for plant operators, measurement institutes and supervising authorities.
Document: references other documents
Document: referenced in other documents
Responsible national committee
NA 134-04-01-04 UA - Measurement of the concentration of CO and hydrocarbons (emissions)