VDI/DIN-Commission on Air Pollution Prevention (KRdL) - Standards Committee
Meteorology - Radiosonde - Part 2: Test method for humidity sensor of radiosonde
Abstract
The purpose of this International Standard is to provide a test method for radiosonde humidity sensors with varying temperature and relative humidity using laboratory setups. The main scope of this International Standard is as follows: (a) technical requirements for laboratory setups needed for the calibration of radiosonde humidity sensors; (b) test procedure for calibrating radiosonde humidity sensors in the range of −70 ℃ – 50 ℃ and 1 % – 100 % (or maximum relative humidity below 0 ℃) (c) uncertainty evaluation method for radiosonde humidity sensors. To be more specific, the requirements for an absolute humidity generator, a test cell, and a precision hygrometer as essential laboratory setups are proposed in part (a). In part (b), the test procedure includes the installation of radiosondes in the test cell, the operation of laboratory setups, and the comparison between the reference relative humidity and the relative humidity measurement by radiosondes. In part (c), the method to evaluate uncertainties related with the reference relative humidity and the radiosonde humidity sensor is proposed.
Begin
2022-05-11
Planned document number
DIN ISO 8932-2
Project number
13402148
Responsible national committee
NA 134-02-01-50 UA - Meteorological measurements