DIN Standards Committee Lighting Technology
DIN EN 61347-2-2
; VDE 0712-32:2012-11
Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps (IEC 61347-2-2:2011); German version EN 61347-2-2:2012
Geräte für Lampen - Teil 2-2: Besondere Anforderungen an gleich- oder wechselstromversorgte elektronische Konverter für Glühlampen (IEC 61347-2-2:2011); Deutsche Fassung EN 61347-2-2:2012
Overview
This part of IEC 61347 specifies particular safety requirements for electronic step-down convertors for use on d.c. supplies of up to 250 V or a.c. supplies of up to 1 000 V, at 50 Hz or 60 Hz. The rated output voltage between conductors and between any conductor and earth is ≤ 50 V r.m.s. at a frequency deviating from the supply frequency, or 120 V ripple free d.c. This controlgear is intended for operation of tungsten-halogen lamps as specified in IEC 60357 and other filament lamps. The limit of 50 V rated output voltage is in accordance with band I of IEC 60449. Particular requirements for electronic step-down convertors with means of protection against overheating are given in Annex C. Particular additional requirements for convertors providing safety extra low voltage (hereinafter SELV), are given in Annex I. Performance requirements are covered by IEC 61047. Plug-in convertors, being part of the luminaire, are covered as for built-in convertors by the additional requirements of the luminaire standard. The responsible committee is DKE/UK 521.3 "Geräte für Lampen" ("Auxiliaries for lamps") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.