DIN Standards Committee Refrigeration Technology
DIN EN 16147
Heat pumps with electrically driven compressors - Testing, performance rating and requirements for marking of domestic hot water units; German version EN 16147:2017 + AC:2017
Wärmepumpen mit elektrisch angetriebenen Verdichtern - Prüfungen, Leistungsbemessung und Anforderungen an die Kennzeichnung von Geräten zum Erwärmen von Brauchwarmwasser; Deutsche Fassung EN 16147:2017 + AC:2017
Overview
This European Standard specifies methods for testing, rating of performance and calculation of water heating energy efficiency of air/water, brine/water, water/water and direct exchange/water heat pump water heaters and heat pump combination heaters with electrically driven compressors and connected to or including a domestic hot water storage tank for domestic hot water production. This European Standard comprises only the testing procedure for the domestic hot water production of the heat pump system. This European Standard only applies to water heaters which are supplied in a package of heat pump and storage tank. In the case of water heaters consisting of several parts with refrigerant connections, this European Standard applies only to those designed and supplied as a complete package. This European Standard does not specify requirements of the quality of the used water. This document (EN 16147:2017) has been prepared by Technical Committee CEN/TC 113 "Heat pumps and air conditioning units", the secretariat of which is held by UNE (Spain). Regarding the German collaboration, the responsible committee is Working Committee NA 044-00-06 AA "Elektromotorisch angetriebene Wärmepumpen und Luftkonditionierungsgeräte" ("Heat pumps with electrically driven compressors") at DIN Standards Committee Refrigeration Technology (FNkä).
Document: references other documents
Document: referenced in other documents
Responsible national committee
NA 044-00-06 AA - Heat pumps with electrically driven compressors and air conditoners
Responsible european committee
CEN/TC 113/WG 10 - Heat pumps for domestic hot water production and revision of EN 16147