DKE German Commission for Electrical, Electronic & Information Technologies of DIN and VDE
DIN EN 62387 Berichtigung 1
; VDE 0492-3 Berichtigung 1:2017-03
Radiation protection instrumentation - Passive integrating dosimetry systems for individual, workplace and environmental monitoring of photon and beta radiation (IEC 62387:2012, modified); German version EN 62387:2016, Corrigendum to DIN EN 62387 (VDE 0492-3):2016-10
Strahlenschutz-Messgeräte - Passive integrierende Dosimetriesysteme zur Personen-, Arbeitsplatz- und Umgebungsüberwachung auf Photonen- und Betastrahlung (IEC 62387:2012, modifiziert); Deutsche Fassung EN 62387:2016, Berichtigung zu DIN EN 62387 (VDE 0492-3):2016-10
Overview
This standard applies to all kinds of passive dosimetry systems that are used for measuring - the personal dose equivalent Hp(10) (for whole body dosimetry), - the personal dose equivalent Hp(3) (for eye lens dosimetry), - the personal dose equivalent Hp(0,07) (for both whole body and extremity dosimetry), - the ambient dose equivalent H*(10) (for environmental dosimetry), or - the directional dose equivalent H '(0,07) (for environmental dosimetry). This standard applies to dosimetry systems that measure external photon and/or beta radiation in the dose range between 0,01 mSv and 10 Sv. The dosimetry systems usually use electronic devices for the data evaluation and thus are often computer controlled. The Corrigendum corrects individual values in the tables. The responsible committee is DKE/GUK 967.3 "Strahlenschutzdosimeter" ("Radiation protection dosemeter") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.