NA 022

DKE German Commission for Electrical, Electronic & Information Technologies of DIN and VDE

Standards [Withdrawn]

DIN EN 50600-2-4 ; VDE 0801-600-2-4:2015-07
Information technology - Data centre facilities and infrastructures - Part 2-4: Telecommunications cabling infrastructure; German version EN 50600-2-4:2015

Title (German)

Informationstechnik - Einrichtungen und Infrastrukturen von Rechenzentren - Teil 2-4: Infrastruktur der Telekommunikationsverkabelung; Deutsche Fassung EN 50600-2-4:2015

Overview

In modern information society, data centres are the control and storage centres for the electronic data exchange. The ever-growing performance requirements for data centres as well as the unlimited growth of their energy demand call for approved technical specifications that enable the planner and the operator to plan, expand and operate a data centre according to the state of the art in a future-proof manner. This includes requirements for the availability of the services of the data centre, its energy efficiency and economic aspects, amongst others. Even though there are standards for components and subsystems used in data centres (for example, for uninterrupted power supply), a standard suitable for the European market for the design, planning, procurement, integration, installations, operation and maintenance of facilities and infrastructures within data centres has so far been missing. Upon German request CENELEC/TC 215 "Electrotechnical aspects of telecommunication equipment" decided to prepare the series of the European Standards EN 50600. The primary function of a data centre is usually the accommodation of a large number of computing and communication devices which effect the design, operation and physical safety. Most data centres can demand special safety requirements. Therefore the planning of a data centre by the planner and the various technical disciplines supporting him/her during planning and execution of the construction of the data centre, such as electrical engineering, machine technology, safety, etcetera, in collaboration with IT and telecommunication staff, network experts, the facility manager, the IT end user and all other employees involved. Part 2-4 addresses the wide range of telecommunications cabling infrastructures within data centres based upon the criteria and classifications for "availability" within EN 50600-1. The standard specifies requirements and recommendations for the following: a) information technology and network telecommunications cabling (for example, SAN and LAN); b) general information technology cabling to support the operation of the data centre; c) telecommunications cabling to monitor and control, as appropriate, power distribution, environmental control and physical security of the data centre; d) other building automation cabling; e) pathways, spaces and enclosures for the telecommunications cabling infrastructures. The standard has been prepared under Mandate M/462 "Standardisation in the field of ICT to enable efficient energy use in fixed and mobile information and communication networks" given to CENELEC by the European Commission and the European Free Trade Association. The responsible committee is Joint Subcommittee DKE/GUK 715.3 "Informationstechnische Verkabelung von Gebäudekomplexen" ("Customer premises cabling") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.

Document: references other documents

Document: referenced in other documents

Responsible national committee

DKE/GK 719 - Rechenzentren  

Edition 2015-07
Original language German
Price from 95.25 €
Table of contents

Contact

Dipl.-Ing.

Thomas H. Wegmann

Merianstr. 28
63069 Offenbach am Main

Tel.: +49 69 6308-315

Send message to contact