DIN 42600-2
Instrument transformers for 50 Hz, Uₘ 0,72 kV to 52 kV - Part 2: Current transformers Uₘ = 0,72 kV and Uₘ = 1,2 kV - Main dimensions

Title (German)

Messwandler für 50 Hz, Uₘ 0,72 kV bis 52 kV - Teil 2: Stromwandler Uₘ = 0,72 kV und Uₘ = 1,2 kV - Hauptmaße

Overview

The DIN 42600 series "Instrument transformers for 50 Hz, Um 0,72 kV to 52 kV" is applicable for the designs and dimensions of instrument transformers for air-insulated indoor installations with maximum equipment voltage from 0,72 kV to 52 kV and consists of the following parts: - Part 1: Basic requirements - Part 2: Current transformers Um = 0,72 kV and Um = 1,2 kV - Main dimensions - Part 3: Voltage transformers Um 12 kV to 36 kV - Large design, main dimensions, indoor type - Part 4: Current Transformers (support-type-insulator) Um = 12 kV - Small design, main dimensions, indoor type - Part 5: Current Transformers (support-type-insulator) Um 12 kV to 36 kV - Large design, main dimensions, indoor type - Part 7: Voltage Transformers Um to 12 kV - Small design, main dimensions, indoor type - Part 8: Current Transformers (support-type-insulators) Um = 12 kV and Um = 24 kV - Narrow design, main dimensions, indoor type - Part 9: Voltage Transformers Um = 12 kV and Um = 24 kV - Narrow design, main dimensions, indoor type. This standard is applicable for instrument transformers for air-insulated indoor installations with maximum equipment voltage from 0,72 kV to 52 kV. Instrument transformers for Um = 3,6 kV and Um = 7,2 kV are preferably manufactured for the design for Um = 12 kV. There are no special design specifications for instrument transformers Um = 52 kV; for this purpose only the general statements of this standard apply. It shall also be applied analogously for transformers for metal-enclosed installations as well as for transformers for outdoor installations of the same voltage levels, provided no other specifications have been made. Part 2: Current transformers Um = 0,72 kV and Um = 1,2 kV - Main dimensions This standard is applicable for current transformers for air-insulated indoor installations with maximum equipment voltage 0,72 kV to 1,2 kV. This standard shall be used in conjunction with DIN 42600-1. Part 3: Voltage transformers Um 12 kV to 36 kV - Large design, main dimensions, indoor type This standard is applicable for voltage transformers for air-insulated indoor installations with maximum equipment voltage from 12 kV to 36 kV - Large design. This standard shall be used in conjunction with DIN 42600-1. Part 4: Current Transformers (support-type-insulator) Um = 12 kV - Small design, main dimensions, indoor type This standard is applicable for current transformers for air-insulated indoor installations with maximum equipment voltage 12 kV - Small design. This standard shall be used in conjunction with DIN 42600-1. Part 5: Current Transformers (support-type-insulator) Um 12 kV to 36 kV - Large design, main dimensions, indoor type This standard is applicable for current transformers for air-insulated indoor installations with maximum equipment voltage 12 kV to 36 kV - Large design. This standard shall be used in conjunction with DIN 42600-1. Part 7: Voltage Transformers Um to 12 kV - Small design, main dimensions, indoor type This standard is applicable for voltage transformers for air-insulated indoor installations with maximum equipment voltage 12 kV - Narrow design. This standard shall be used in conjunction with DIN 42600-1. Part 8: Current Transformers (support-type-insulators) Um = 12 kV and Um = 24 kV - Narrow design, main dimensions, indoor type This standard is applicable for current transformers for air-insulated indoor installations with maximum equipment voltage from 12 kV to 24 kV - Narrow design. This standard shall be used in conjunction with DIN 42600-1. Part 9: Voltage Transformers Um = 12 kV and Um = 24 kV - Narrow design, main dimensions, indoor type This standard is applicable for voltage transformers for air-insulated indoor installations with maximum equipment voltage from 12 kV to 24 kV - Narrow design. The responsible committee is K 471 "Messwandler" ("Instrument transformers") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.

Document: references other documents

Document: referenced in other documents

Responsible national committee

DKE/K 471 - Messwandler  

Edition 2013-10
Original language German
Price from 42.10 €
Table of contents

Contact

Bernd Stäblein

Merianstr. 28
63069 Offenbach am Main

Tel.: +49 69 6308-430

Send message to contact