NA 022

DKE German Commission for Electrical, Electronic & Information Technologies of DIN and VDE

Standards [Withdrawn]

DIN EN 60904-5 ; VDE 0126-4-5:2011-12
Photovoltaic devices - Part 5: Determination of the equivalent cell temperature (ECT) of photovoltaic (PV) devices by the open-circuit voltage method (IEC 60904-5:2011); German version EN 60904-5:2011

Title (German)

Photovoltaische Einrichtungen - Teil 5: Bestimmung der gleichwertigen Zellentemperatur von photovoltaischen (PV) Betriebsmitteln nach dem Leerlaufspannungs-Verfahren (IEC 60904-5:2011); Deutsche Fassung EN 60904-5:2011

Overview

This part of IEC 60904 describes the preferred method for determining the equivalent cell temperature (ECT) of PV devices (cells, modules and arrays of one type of module), for the purposes of comparing their thermal characteristics, determining the nominal operating cell temperature (NOCT) and translating measured I-V characteristics to other temperatures. This standard applies to linear devices with logarithmic VOC dependence on irradiance and in stable conditions. The standard may be used for all technologies but one has to verify that there is no preconditioning effect influencing the measurement. When temperature sensors, such as thermocouples, are used to determine the cell temperature of PV devices under natural or simulated steady-state irradiance, two main problems arise. First, a considerable spread of temperature can be observed over the area of the module. Second, as the solar cells are usually not accessible, sensors are attached to the back of the module and the measured temperature thus is influenced by the thermal conductivity of the encapsulant and back materials. These problems are aggravated when determining the equivalent cell temperature for on-site measurements of array performance where all cells have slightly different temperatures and one cannot easily determine the average cell temperature. The equivalent cell temperature (ECT) is the average temperature at the electronic junctions of the device (cells, modules, arrays of one type of module) which equates to the current operating temperature if the entire device were operating uniformly at this junction temperature. The responsible committee is K 373 "Photovoltaische Solarenergie-Systeme" ("Solar photovoltaic energy systems") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.

Document: references other documents

Responsible national committee

DKE/K 373 - Photovoltaische Solarenergie-Systeme  

Edition 2011-12
Original language German
Price from 41.72 €
Table of contents

Contact

Dominika Radacki

Merianstr. 28
63069 Offenbach am Main

Tel.: +49 69 6308-249

Send message to contact