NA 022

DKE German Commission for Electrical, Electronic & Information Technologies of DIN and VDE

Standards [CURRENT]

DIN EN 61558-2-5 ; VDE 0570-2-5:2011-03
Safety of transformers, reactors, power supply units and combinations thereof - Part 2-5: Particular requirements and tests for transformer for shavers, power supply units for shavers and shaver supply units (IEC 61558-2-5:2010); German version EN 61558-2-5:2010

Title (German)

Sicherheit von Transformatoren, Drosseln, Netzgeräten und entsprechender Kombinationen - Teil 2-5: Besondere Anforderungen und Prüfungen an Transformatoren für Rasierer, Netzgeräte für Rasierer und Rasiersteckdosen-Einheiten (IEC 61558-2-5:2010); Deutsche Fassung EN 61558-2-5:2010

Overview

This part of IEC 61558 deals with the safety of shaver transformers, power supply units incorporating a shaver transformer, and shaver supply units. Shaver transformers incorporating electronic circuits are also covered by this standard. Safety includes electrical, thermal, mechanical and chemical aspects. Unless otherwise specified, the term transformer covers shaver transformers and power supply units incorporating shaver transformers and shaver supply units. This part is applicable to stationary, single phase air-cooled (natural or forced), independent or associated dry-type transformers. The windings may be encapsulated or non-encapsulated. This standard is applicable to transformers and power supply (linear) with internal operational frequencies not exceeding 500 Hz. This standard shall be used in combination with Part 2-16 for switch mode power supply units (SMPS) and is also applicable to power supplies with internal operational frequencies higher than 500 Hz. Where the two requirements are in conflict, the most severe takes precedence. The rated supply voltage does not exceed 250 V a.c., and the rated supply frequency does not exceed 500 Hz. The rated output is not less than 20 VA and does not exceed 50 VA. The no-load output voltage does not exceed 275 V a.c and the rated output voltage does not exceed 250 V a.c. This part is not applicable to external circuits and their components intended to be connected to the input and output terminals or socket-outlets of the transformers. Transformers covered by this part are used in applications where double or reinforced insulation between circuits is required by the installation rules for bathrooms and similar locations, or by the appliance specifications. The responsible Committee is K 323 "Transformatoren, Drosseln, Netzgeräte und entsprechende Kombinationen" ("Transformers, reactors, power supply units and corresponding combinations thereof") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.

Document: references other documents

Document: referenced in other documents

Responsible national committee

DKE/K 323 - Transformatoren, Drosseln, Netzgeräte und entsprechende Kombinationen  

Edition 2011-03
Original language German
Price from 52.28 €
Table of contents

Contact

Alexander Nollau

Merianstr. 28
63069 Offenbach am Main

Tel.: +49 69 6308-223
Fax: +49 69 6308-9223

Send message to contact