NA 022

DKE German Commission for Electrical, Electronic & Information Technologies of DIN and VDE

Project

Overhead distribution cables of rated voltage U₀/U (Uₘ): 0,6/1 (1,2) kV; German and English version prHD 626 S2:2020

Abstract

Applies to cables of rated voltage U0/U (Um) = 0,6/1 (1,2) kV used in overhead power distribution systems mainly for public distribution, of maximum system voltage not exceeding 1,2 kV. This part (Part 1) specifies the general requirements applicable to these cables, unless otherwise specified in the particular sections of this HD. Test methods are specified in EN 60228, EN 60332-1 series, EN 60811 series and in HD 605 or in Part 2 of this HD. The particular types of cables are specified in Parts 3 to 10. Collates and specifies the test methods to be used for testing polymeric insulated and sheathed electric cables, of rated voltage up to and including 0,6/1 kV, intended mainly for public distribution systems. Test methods in this part are additional to those already harmonized, e.g. EN 60811 and HD 605. In each case, these HDs give complementary information needed for the practical application to each specific type. Therefore, the present part as such is not sufficient for carrying out and evaluating the tests on electric cables. Full test conditions (e.g. temperatures, duration) and/or test requirements are not specified in this HD. Such data needed to carry out the tests are given in the particular sections. Specifies the construction, dimensions and test requirements for bundle assembled cores for overhead distribution and service (Type 3A-1) used in A.C. and three-phase system for rated voltage (U) of 1 kV for fixed installations.

Begin

2022-07-21

Planned document number

DIN VDE 0276-626

Project number

02231131

Responsible national committee

DKE/UK 411.1 - Starkstromkabel  

draft standard

Overhead distribution cables of rated voltage U₀/U (Uₘ): 0,6/1 (1,2) kV; German and English version prHD 626 S2:2020
2023-05
Order from DIN Media

previous edition(s)

Power cables - Overhead distribution cables of rated voltage U₀/U(Uₘ): 0,6/1 (1,2) kV; Amendment A1; German version HD 626 S1/A1:1997
1998-07

Order from DIN Media

Power cables Part 626- Overhead distribution cables of rated voltage U₀/U(Uₘ):0,6/1 (1,2) kV; German version HD 626 S1 Parts 1, 2 and 4 F-1:1996
1997-01

Order from DIN Media

Contact

Jürgen Schütz

Merianstr. 28
63069 Offenbach am Main

Tel.: +49 69 6308-497
Fax: +49 69 6308-9497

Send message to contact