DKE German Commission for Electrical, Electronic & Information Technologies of DIN and VDE
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-21: Tests - Composite temperature/humidity cyclic test (IEC 86B/4468/CD:2021); Text in German and English
Abstract
The purpose of this part of IEC 61300 is to determine the resistance of a fibre optic device or 80 component to the deteriorative effects of high temperature, humidity and cold conditions. It is intended to reveal defects in a device under test (DUT) caused by breathing as opposed to absorption of moisture. The test covers the effect of the freezing of trapped water in cracks and fissures as well as condensation. However, the degree of condensation will vary depending on the size and thermal mass of the DUT.
Begin
2021-05-31
Planned document number
DIN EN IEC 61300-2-21
Project number
02230309
Responsible national committee
DKE/UK 412.7 - LWL-Verbindungstechnik und passive optische Komponenten
draft standard
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-21: Tests - Composite temperature/humidity cyclic test (IEC 86B/4468/CD:2021); Text in German and English
2022-10
Order from DIN Media